InteliATS NT PWR

Order code: IA-NT PWR

This product is obsolete, availability might be limited. Check out its successor, InteliATS2 70
InteliATS NT Power (PWR) is an Automatic Transfer Switch (ATS) controller for easy and fast switching between two independent power sources. It monitors and controls the mains supply and its voltage, frequency, and current with the possibility to connect to a single gen-set. The InteliATS NT PWR is easy to use and configure using ComAp’s LiteEdit, PC tool for configuring gen-set controllers and their peripherals. 
 
  • Mains-to-Generator application      
  • Closed Transition  
  • Easy configuration and use    
  • Precise current measurement         

    InteliATS NT PWR

Easy to install, configure and use, the InteliATS NT PWR will ensure swift switch from one power source to another.

The InteliATS NT PWR offers: 

  • Mains-to-Generator application 
  • Closed Transition (short time parallel), ensuring transition initiates only when both breakers/contactors are in sync. This transition is suitable for systems where no break (no blackout) changeover is required. Option to control motorised circuit breakers or contractors or changeover switches
  • Option to control motorised circuit breakers, contractors, or changeover switches
  • Simple configuration, monitoring and control both on-site and remotely (with optional expansion card) thanks to the settings available through LiteEdit, ComAp’s PC monitoring and configuration tool
  • Mains monitoring (one or three phases) for under and over voltage, under and over frequency, and voltage disbalance
  • Remote gen-set start 
  • Change over for mains and generator contractors
  • True voltage and current RMS measurement 
  • Test run scheduler
  • Three-phase power measurement
  • Detailed Real Time Clock event and performance log 
  • AirGate to connect to your equipment remotely, without worrying about your asset’s IP address* 
  • Remote control and monitoring of your gen-set operations with WebSupervisor, our cloud-based fleet management tool* 
  • Multilingual support
  • Seven binary inputs and seven binary outputs

* Optional plug-in module

    Accessories

    Frequently Asked Questions

    Can I unlock my controller?

    If you have forgotten your controller password, it can be found using the password decode function.

    You will need the following information about your device:

    • serial number
    • "password decode" number
    Both numbers can be obtained through the monitoring software relevant to the device.
    • Serial number is available in Controller info
    • Password decode number is available in Values / Info

    You can also show these numbers on your device's display. Typically, this requires a sequence or combination of buttons to be pressed. Details can be found typically in the device Operator guide.

    Once you have these numbers, please contact your ComAp distributor and they will help you get your password back.

     

    How do I connect to my ComAp controller? What types of connections are supported?

    ComAp offers a wide range of options to connect to your controller:

    • RS232 / RS485
    • USB - USB A<->B (usually a printer cable)
    • Internet connection - LAN, GPRS, 3G, 4G

    Note that some connection types require you to use a communication module (plug-in eg a RS232 card) or communication bridge (external device eg Internet Bridge NT).

    Each ComAp device usually allows for multiple ways of connection. The simplest one supported by the majority of our devices is the RS232 (serial) connection. For this, you need an RS232 cable (null modem) and if your PC is not equipped with an RS232 port you need a USB<->RS232 converter.
    USB connections are very common. Almost all ComAp devices support connection using simple USB A<->B cable (printer cable) for easy configuration. Some devices can be powered from the USB port for programming to allow easy configuration right on your desk.
    Other connection types: Internet connection (LAN, GPRS, 3G, 4G), Modbus RTU, Modbus TCP, SNMP, AirGate, Modem.
    Note that some connection types require you to use a communication module (plug-in eg a RS232 card) or communication bridge (external device eg Internet Bridge NT). Not all types of connection are possible on each device. You can find all the details related to this topic in your device's Comprehensive guide or Communication guide.
     
    Detailed information about connection to:
    InteliLite NT, InteliATS NT, InteliCompact NT is available IL-NT, IA-NT, IC-NT Communication Guide (page 21)
    InteliGen-NT, InteliSys-NT, InteliMains-NT is available in IGS-NT Communication Guide (page 19)
    InteliLite is available in Global Guide InteliLite AMF25 Global Guide (page 126)

     

    How do I change the controller firmware? Where can I get the latest firmware?

    You can download the latest firmware package on the webpage of the device. You can easily navigate there through the ‘Products’ section or just use the Search function. If you cannot find the firmware on the website or if you require different than the offered version do not hesitate to contact our support team.

    The firmware upgrade itself is easy to perform. You need the appropriate configuration software and a connection to the controller (preferably a direct connection). Prior to initiating the update process, we strongly recommend you to save a complete backup of your device.

    It usually consists of several steps:
    • Create a controller back up.
    • Update the device firmware. It will contain default Configuration Archive and default Application.
    • Change the Application (SPtM, MiNT, MCB, MGCB, BTB, etc) to the required type (by programming appropriate default archive to the controller).
    • Use the Import Configuration Wizard to restore your previous configuration. In some cases manual interventions might be needed during this step.
    • Optional: Update the connected display firmware or device communication module firmware.
    Should you be unsuccessful in programming the new version, the rollback procedure is to install previous firmware version and use your back up to restore the controller to its original state before the firmware upgrade was attempted.

    What do SPtM, MINT, MGCB stand for?

    SPtM = Single Parallel to Mains
    MINT = Multiple gen-sets with INTernal sync and load sharing
    MGCB = Master Generator Circuit Breaker

    ComAp’s world is full of abbreviations but once you get a basic understanding of their meanings, you will find them useful when reading the documentation or communicating with us.
     

    Do you support communication to (IVECO, Cummins, MAN, VOLVO, etc.) ECUs?

    Yes, ComAp devices are capable of communication with electronic engine control units (ECUs) from the majority of engine manufacturers.

    Typically, you connect the ECU directly to the controller using CAN bus. If the ECU does not support the J1939 communication protocol you need to use a communication interface either on the ECU side (such as SAM CCB2 or SmartConnect modules) or on the ComAp side using the I-CB communication bridge.

    The communication is typically bi-directional so we support reading of values from the ECU as well as sending commands to the ECU (Start, Stop, etc) and controlling the engine RPM.

    For details including physical connection, configuration steps and troubleshooting help please consult the Electronic Engines Support Guide available on this website.

    Local support you can count on

    Your operation depends on everything running smoothly. Our experts are here to make sure of that. We offer:

    • 24-hour support on working days
    • Local contacts in 179 countries
    • Remote and in-person trainings and a range of support materials
    • Expert consultation, troubleshooting, and much more

    Contact your local ComAp representative

    Didn't find what you were looking for? Contact us, we’ll be happy to answer any questions you may have and help you with your business needs.

    Interested in another country? Find your local representative

    Our website uses cookies and similar technologies to provide you the best experience and to understand how you use our site.

    You may either „Accept all“ by which you agree with using functional, analytical and marketing cookies. By pressing „Revoke“ only necessary cookies shall be allowed to enable the website and applications function correctly. To revoke your consent you can do it from footer menu in Change cookie preferences section.

    You can find more information on the Cookie page and the Privacy section .